Är du intresserad av servicekontrakt eller billiga leasingerbjudanden? Vi hjälper dig gärna!

Cisco - UCSC-C240-M4SX - UCS C240 M4 High-Density Rack Server Small Form Factor Hard Disk Drive

  • 10128608-014
Artikel nr.: 10128608-003
på förfrågan

Leveranstid ca 5 dagar

Artikel nr.: 10128608-014
på förfrågan

Leveranstid ca 5 dagar

Informera mig så snart artikeln är tillgänglig.

  • 3 års garanti
  • Frakt samma dag via UPS
  • Personal Account Manager
  • Teknisk support och konfigurationer

Produktbeskrivning

Cisco - UCSC-C240-M4SX - UCS C240 M4 High-Density Rack Server Small Form Factor Hard Disk Drive Model - Server - Serial Attached SCSI (SAS)

Herstellerinformationen:
Cisco Systems GmbH
Parkring 20
85748 Garching Deutschland
0800 - 187 36 52
+49 (0)89 51657 1001
https://www.cisco.com/c/m/de_de/impressum.html
Card Reader
Supported Flash Memory Cards: SD Memory Card
Dimensions & Weight
Depth: 73.8 cm
Height: 8.7 cm
Width: 44.8 cm
Environmental Parameters
Humidity Range Operating: 10 - 90% (non-condensing)
Max Operating Temperature: 35 °C
Min Operating Temperature: 5 °C
Expansion / Connectivity
Bays: 24 (total) / 24 (free) x hot-swap 2.5" SFF
Interfaces: 1 x serial - RJ-45 ¦ 2 x USB 3.0 ¦ 2 x management (NIC) - RJ-45 ¦ 1 x management ¦ 1 x VGA ¦ 1 x KVM
Slots: 2 (total) / 2 (free) x CPU ¦ 24 (total) / 24 (free) x DIMM 288-pin ¦ 2 SD card
General
Built-in Devices: Backplane
Hot-Swap Bays Qty: 24
Product Form Factor: Rack-mountable - 2U
Server Scalability: 2-way
Type: Server
Graphics Controller
Graphics Processor: Matrox G200e
Type: Integrated
Video Interfaces: VGA
Video Memory: 256 MB
Hard Drive
Type: No HDD
Miscellaneous
Compliant Standards: CISPR 22 Class A, BSMI CNS 13438 Class A, CISPR 24, EN 61000-3-2, EN 61000-3-3, EN55024, EN55022 Class A, AS/NZS 60950-1, ICES-003 Class A, UL 60950-1, UL 60950-1 Second Edition, Directive 2004/108/EC, CSA C22.2 No. 60950-1 Second Edition, EN 60950-1 Second Edition, IEC 60950-1 Second Edition, Directive 2006/95/EC, KN24, KN22 Class A, GB4943.1-2001, EN 300 386, EN 300386
Included Accessories: SAS expander
Monitor
Monitor Type: None.
Networking
Data Link Protocol: Ethernet, Fast Ethernet, Gigabit Ethernet
Ethernet Controller: 2 x Intel I350
Optical Storage
Type: No optical drive
Power
Device Type: Power supply - hot-plug
Installed Qty: 0
Max Supported Qty: 2
Power Redundancy: Optional
Processor / Chipset
CPU: No CPU
CPU Socket: LGA2011-v3 Socket
CPU Upgradability: Upgradable
Chipset Type: Intel C612
Max CPU Qty: 2
RAM
Features: Registered, single rank, Memory Mirroring, dual rank, Load-Reduced DIMM (LRDIMM)
Form Factor: DIMM 288-pin
Installed Size: 0 GB / 768 GB (max)
RAM Supported: PC4-17000 384 GB registered - ECC ¦ PC4-17000 768 GB Load-Reduced - ECC
Slots: 24 (Total) / 24 (empty)
Technology: DDR4 SDRAM - ECC
Senast betraktad