Postavke kolačića
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the usability of this website, serve for direct advertising or simplify interaction with other websites and social networks, will only be used with your consent.
Konfiguracija
Tehnički je potrebno
Ovi su kolačići potrebni za osnovne funkcije trgovine.
CSRF token
Mijenjanje valute
Odabrana trgovina
PayPal-Zahlungen
Postavke kolačića
Poziv
Prepoznavanje kupca
Prilagođeno predmemoriranje
Sve Kolačiće odbijam
Sve kolačiće prihvaćam
Trenutne cijene
Komfortabilne funkcije
Ovi se kolačići koriste kako bi doživljaj kupovine bio još privlačniji, na primjer, da prepoznaju posjetitelja.
Lista želja
Statistikak & praćenje
Partnerski program
Prepoznavanje krajnjeg uređaja
- Br. artikla: 10104101-003
Obavijestite me kada je ovaj artikl opet raspoloživ.
- 3 godine jamstva
- Pošiljka istog dana putem UPS-a
- Personalni account amanger
- Tehnička podrška i konfiguracija
Produktbeschreibung
HP 2324fc DC Modular Smart Array
Chassis | |
---|---|
Installed Devices / Modules Qty: | 0 |
Supported Devices / Modules Qty: | 24 |
Supported Drives: | SATA-300 / SAS |
Dimensions & Weight | |
---|---|
Depth: | 51.5 cm |
Height: | 8.7 cm |
Weight: | 19.5 kg |
Width: | 44.6 cm |
Environmental Parameters | |
---|---|
Humidity Range Operating: | 10 - 90% |
Max Operating Temperature: | 40 °C |
Min Operating Temperature: | 5 °C |
Expansion / Connectivity | |
---|---|
Expansion Bays: | 24 (total) / 24 (free) - 2.5" |
Interfaces: | 2 x serial RS-232 - 9 pin D-Sub (DB-9) ¦ 2 x management - RJ-45 ¦ 4 x 4Gb Fibre Channel ¦ 2 x SAS |
General | |
---|---|
Device Type: | Hard drive array |
Enclosure Type: | Rack-mountable - 2U |
Hard Drive | |
---|---|
Interface Type: | SATA 3Gb/s / SAS |
Miscellaneous | |
---|---|
Compliant Standards: | CISPR 22 Class A, CISPR 24, EN55022, EN55024, ICES-003 Class A, RoHS, UL 60950-1, IEC 60950-1, EN 60950-1, CSA C22.2 No. 60950-1-03, FCC CFR47 |
Pricing Type: | Remarketed |
Power | |
---|---|
Power Device: | Internal power supply - hot-plug |
Power Redundancy: | Yes |
Power Redundancy Scheme: | 1+1 |
Storage | |
---|---|
HDD Array External Interface: | 4Gb Fibre Channel |
Max Supported Capacity: | 16 TB |
Maximum LUNs: | 512 |
Storage Controller | |
---|---|
Cache / Buffer Size (Max): | 1 GB |
Data Transfer Rate: | 300 MBps |
Interface Type: | SATA 3Gb/s / SAS |
RAID Level: | RAID 0, RAID 1, RAID 3, RAID 5, RAID 6, RAID 10, RAID 50 |
Supported Devices: | Disk array (RAID) |
Type: | 2 x RAID (4Gb Fibre Channel) |
System Requirements | |
---|---|
OS Required: | Red Hat Linux 5.0, SuSE Linux 10.0, Microsoft Windows Server 2003 x64 Edition, Microsoft Windows 2003, Microsoft Windows 2003 R2, VMware ESX Server |
Zadnje viđeno