This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the usability of this website, serve for direct advertising or simplify interaction with other websites and social networks, will only be used with your consent.
Konfiguracija
Tehnički je potrebno
Ovi su kolačići potrebni za osnovne funkcije trgovine.
CSRF token
Mijenjanje valute
Odabrana trgovina
PayPal-Zahlungen
Postavke kolačića
Poziv
Prepoznavanje kupca
Prilagođeno predmemoriranje
Sve Kolačiće odbijam
Sve kolačiće prihvaćam
Trenutne cijene
Komfortabilne funkcije
Ovi se kolačići koriste kako bi doživljaj kupovine bio još privlačniji, na primjer, da prepoznaju posjetitelja.
Lista želja
Statistikak & praćenje
Partnerski program
Prepoznavanje krajnjeg uređaja
Cisco - DS-C9148S-48PK9 - MDS 9148S - Switch - Rack-Modul
- Br. artikla: 10125349-014
Obavijestite me kada je ovaj artikl opet raspoloživ.
- 3 godine jamstva
- Pošiljka istog dana putem UPS-a
- Personalni account amanger
- Tehnička podrška i konfiguracija
Produktbeschreibung
MDS 9148S - Switch - Rack-Modul
Dimensions & Weight | |
---|---|
Depth: | 41.5 cm |
Height: | 4.37 cm |
Weight: | 9 kg |
Width: | 43.59 cm |
Environmental Parameters | |
---|---|
Humidity Range Operating: | 10 - 90% (non-condensing) |
Humidity Range Storage: | 10 - 95% (non-condensing) |
Max Operating Temperature: | 40 °C |
Max Storage Temperature: | 70 °C |
Min Operating Temperature: | 0 °C |
Min Storage Temperature: | -40 °C |
Expansion / Connectivity | |
---|---|
Interfaces: | 1 x 1000Base-T RJ-45 management ¦ 1 x serial (RS-232) RJ-45 management ¦ 1 x USB Type A ¦ 48 x 16Gb Fibre Channel SFP+ |
General | |
---|---|
Authentication Method: | RADIUS, TACACS+, Secure Shell v.2 (SSH2), LDAP, Active Directory |
Device Type: | Switch - 48 ports - Managed |
Enclosure Type: | Back to front airflow rack-mountable 1U |
Encryption Algorithm: | AES |
Features: | Auto-sensing per device, ISL support, Virtual Route Redundancy Protocol (VRRP) support, Access Control List (ACL) support, Quality of Service (QoS), Remote Switch Port Analyzer (RSPAN), role based access control, Registered State Change Notification (RSCN) support, SFTP client |
Fibre Channel: | FC-DA, FC-FLA, FC-FS, FC-GS-3, FC-GS-4, FC-MI, FC-PH, FC-PH-2, FC-PH-3, FC-PI, FC-PLDA, FC-SB-2, FC-SB-3, FC-SW-2, FC-SW-3, FC-Tape, FC-VI, FC-SP, FCP-4, FC-BB-2, FCP, FCP-2, FC-PI-2, FC-BB-5, FC-BB-3, FC-FS-2, FC-GS-5, FC-SW-4, FCP-3, FC-LS, FC-MI-2, FC-PI-4, FC-FS-3, FC-GS-6, FC-PI-3, FC-SW-5, FC-BB-4, FC-IFR, FAIS, FAIS-2, FC-PI-5, FC-LS-2, FC-SP-2, FC-SB-4, FC-DA-2, FC-MI-3, FC-MSQS, FC-BB-6 |
Ports: | 48 x 16Gb Fibre Channel SFP+ |
Remote Management Protocol: | RMON, SNMP 3, HTTP, SMI-S, SSH-2, CLI |
Subtype: | Fibre Channel |
Miscellaneous | |
---|---|
Compliant Standards: | CISPR 22 Class A, EN 60950, EN 61000-3-2, IEC 60950, EN 61000-3-3, EN55024, EN55022 Class A, UL 60950, EN50082-1, EN 61000-6-1, ACA TS001, AS/NZS 3260, EMC, ICES-003 Class A, FIPS 140-2, FCC CFR21 Part 1040, EN 60825, IEC 60825, CAN/CSA C22.2 No. 60950 |
Power | |
---|---|
Installed Qty: | 2 (installed) / 2 (max) |
Power Device: | Internal power supply - hot-plug |
Power Provided: | 300 Watt |
Power Redundancy: | Yes |
Power Redundancy Scheme: | 1+1 |
Voltage Required: | AC 120/230 V (50/60 Hz) |
Software / System Requirements | |
---|---|
Software Included: | Cisco Data Center Network Manager (DCNM) for SAN Advanced Edition, Cisco MDS 9000 Family Enterprise Package |