Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the usability of this website, serve for direct advertising or simplify interaction with other websites and social networks, will only be used with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
Allow all cookies
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Decline all cookies
Individual prices
PayPal payments
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Statistics & Tracking
Affiliate program
Track device being used
- Order number: 10123858-003
Please inform me as soon as the product is available again.
- 3 year warranty
- Same day shipments via UPS
- personal account manager
- technical support and configurations
Product Description
MGE Galaxy 5500 - (Offline-) USV
Battery | |
---|---|
Recharge Time: | 10 hours |
Run Time (Up To): | 6 min at full load ¦ 19 min at half load |
Voltage Provided: | 432 V |
Dimensions & Weight | |
---|---|
Depth: | 85 cm |
Height: | 190 cm |
Weight: | 975 kg |
Width: | 111 cm |
Dimensions & Weight (Shipping) | |
---|---|
Shipping Depth: | 96 cm |
Shipping Height: | 203 cm |
Shipping Width: | 113 cm |
Environmental Parameters | |
---|---|
Humidity Range Operating: | 0 - 95% |
Max Operating Temperature: | 40 °C |
Min Operating Temperature: | 0 °C |
Sound Emission: | 55 dBA |
Expansion / Connectivity | |
---|---|
Expansion Slots: | 2 SmartSlot |
Interfaces: | 1 x EPO (emergency power off) |
General | |
---|---|
Device Type: | UPS - Power Factor Correction (PFC) - external |
Miscellaneous | |
---|---|
Compliant Standards: | TUV, ISO 9001, VDE, IEC 62040-3, IEC 62040-2, IP20, IEC 62040-1-2 |
Features: | Audible alarm, emergency power off, LCD display, built-in maintenance bypass, built-in static bypass, LED indicators, predicitive failure notification, IGBT rectifier |
Networking | |
---|---|
Remote Management Interface: | Ethernet |
Remote Management Protocol: | SNMP, Telnet, HTTP |
Power Device | |
---|---|
Circuit Protection: | Circuit breaker |
Efficiency: | 92.5% |
Frequency Provided: | 50/60 Hz |
Frequency Required: | 45 - 65 Hz |
Input Connectors: | 2 x hardwire 4-wire (3PH + G), hardwire 4-wire (3PH + N) |
Input Voltage: | AC 380/400/415 V |
Input Voltage Range: | AC 323 - 437 / 340 - 460 / 353 - 477 V |
Input Wiring: | 3-phase |
Max Electric Current: | 115 A |
Output Voltage: | AC 380/400/415 V ± 2% - 50/60 Hz |
Output Waveform: | Sinewave |
Power Capacity: | 54 kW / 60000 VA |
Power Output Connectors Details: | 1 x hardwire 4-wire (3PH + G) |
UPS Technology: | On-line |